{"id":43276,"date":"2024-12-20T14:11:21","date_gmt":"2024-12-20T07:11:21","guid":{"rendered":"https:\/\/lacviet.vn\/?p=43276"},"modified":"2025-02-18T15:33:10","modified_gmt":"2025-02-18T08:33:10","slug":"tieu-chuan-nhiet-do-phong-server","status":"publish","type":"post","link":"https:\/\/lacviet.vn\/en\/tieu-chuan-nhiet-do-phong-server\/","title":{"rendered":"Standard room temperature, server according to international regulations from ASHRAE"},"content":{"rendered":"<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">In the digital era system <a href=\"https:\/\/lacviet.vn\/en\/servers\/\">server server<\/a> plays an important role in infrastructure, information technology, business. Maintaining room temperature server in the standard not only ensures the performance, but also help increase equipment life, reduce risk of interrupting operation. However, many businesses still have not mastered the standard required temperature, leading to the losses significantly.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">This article will <a href=\"https:\/\/lacviet.vn\/en\/\">Lac Viet<\/a> will provide comprehensive information on <\/span><b>standard room temperature, server<\/b><span style=\"font-weight: 400;\">from the importance, standard specific to the technology solutions support.<\/span><\/p>\n<h2>1. Standard room temperature, server what is?<\/h2>\n<blockquote>\n<p style=\"text-align: justify;\"><b>Standard room temperature, server<\/b><span style=\"font-weight: 400;\"> is specified about the ideal temperature to ensure the equipment in the server room, stable operation, safety and optimal performance. According to the recommendations of <\/span><b>American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE)<\/b><span style=\"font-weight: 400;\">temperature , server room, ideally located in the range from <\/span><b>18\u00b0C to 27\u00b0C<\/b><span style=\"font-weight: 400;\"> (64,4\u00b0F to 80,6\u00b0F).<\/span><\/p>\n<\/blockquote>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">This standard not only help protect the hardware from overheating, but also minimize the risk of such failure, optimize operating costs and extend the life system.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Server room is where the focus of high-tech equipment such as servers, storage, network equipment. Not maintain the temperature in the safety threshold will be:<\/span><\/p>\n<ul style=\"text-align: justify;\">\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">According to research from Uptime Institute, the temperature exceeds the standards can reduce equipment life up to <\/span><b>50%<\/b><span style=\"font-weight: 400;\"> due to the components of impaired quality.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">A survey of ITIC (Information Technology Intelligence Consulting) for see <\/span><b>76% of business<\/b><span style=\"font-weight: 400;\"> recorded incidents server occurs due to temperature error exceeds the threshold.<\/span><\/li>\n<\/ul>\n<ul style=\"text-align: justify;\">\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Equipment operation under high temperature will be prone to overload, lead to deterioration in performance.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Increased risk of disruption system<\/b><span style=\"font-weight: 400;\">: System might experience bugs or stop functioning due to excessive heat, which causes interruption of business operations. The ideal temperature to help reduce the error rate of the system down to only <\/span><b>0,8%\/year<\/b><span style=\"font-weight: 400;\">while at temperatures higher than 5\u00b0C compared to standard, this rate increased <\/span><b>2,5%\/year<\/b><span style=\"font-weight: 400;\">.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Rising cost of repair and maintenance<\/b><span style=\"font-weight: 400;\">: Hardware failure usually occurs when the temperature exceeds the safety threshold, the cost is not worth having. A report by Schneider Electric (2023) shows the temperature maintained in the ideal can reduce maintenance costs up to <\/span><b>30%<\/b><span style=\"font-weight: 400;\">thanks reduce the load for the cooling system.<\/span><\/li>\n<\/ul>\n<h2>2. Standard room temperature, server according to international regulations<\/h2>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\"><a href=\"https:\/\/www.ashrae.org\/\" target=\"_blank\" rel=\"nofollow noopener\">Engineers association of Heat and cold air conditioning, United States<\/a> (ASHRAE) has launched the international standards on room temperature server to ensure optimum performance for the system. Accordingly, the ideal temperature recommended range:<\/span><\/p>\n<ul style=\"text-align: justify;\">\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>From 18\u00b0C to 27\u00b0C<\/b><span style=\"font-weight: 400;\">: This is the limit optimized to ensure stable operation of the IT equipment.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Relative humidity from 40% to 60%<\/b><span style=\"font-weight: 400;\">: Humidity is too high can cause the risk of condensation of water vapor, while the humidity is too low to lead to static damage components.<\/span><\/li>\n<\/ul>\n<p style=\"text-align: justify;\"><b>Performance<\/b><span style=\"font-weight: 400;\">:<\/span><\/p>\n<ul style=\"text-align: justify;\">\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">At temperatures below 18\u00b0C: the System may not operate efficiently because the components do not reach a state of heat ideal.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">On 27\u00b0C: the Risk of overheating, causing the CPU decreased pulse, causing a delay or loss of stability.<\/span><\/li>\n<\/ul>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Business priority should periodically check system temperature control, ensure compliance with international standards. Investing in advanced technologies such as IoT, sensors, smart temperature, the cooling system modern not only help control the temperature effectively, but also bring peace of mind in the operating system server.<\/span><\/p>\n<h2>3. The factors affecting the room temperature, server<\/h2>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Room temperature server is affected from many factors, including the cooling system, space design, room, server, download the heat from the device. Below is the detailed analysis for business to understand to choose the right solution.<\/span><\/p>\n<p style=\"text-align: center;\"><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-43427\" src=\"https:\/\/lacviet.vn\/wp-content\/uploads\/2024\/12\/tieu-chuan-nhiet-do-phong-server-1.png\" alt=\"\" width=\"800\" height=\"500\" srcset=\"https:\/\/lacviet.vn\/wp-content\/uploads\/2024\/12\/tieu-chuan-nhiet-do-phong-server-1.png 800w, https:\/\/lacviet.vn\/wp-content\/uploads\/2024\/12\/tieu-chuan-nhiet-do-phong-server-1-768x480.png 768w, https:\/\/lacviet.vn\/wp-content\/uploads\/2024\/12\/tieu-chuan-nhiet-do-phong-server-1-18x12.png 18w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<h3>3.1. Cooling system (Cooling Systems)<\/h3>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">The cooling system is the most important factor in maintaining room temperature, server stability. A cooling system efficiency not only helps to control the temperature but also save the energy, prolong the service life of equipment.<\/span><\/p>\n<p style=\"text-align: justify;\"><b>System air conditioner (CRAC\/CRAH): <\/b><span style=\"font-weight: 400;\">The air-conditioning system, CRAC (Computer Room Air Conditioning) or CRAH (Computer Room Air Handler) is designed specifically for server room to provide cooling capacity accurate to control moisture effectively.<\/span><\/p>\n<ul style=\"text-align: justify;\">\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">CRAC use cooling technology based on compressed air, which is often applied in the server room standards.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">CRAH line use cool air from the system of cold water, more efficient in terms of energy but require the cost of the initial investment is high.<\/span><\/li>\n<\/ul>\n<p style=\"text-align: justify;\"><b>Cooling technology liquid (Liquid Cooling): <\/b><span style=\"font-weight: 400;\">This technology is becoming increasingly popular, especially in the large data center or server room, there are device density is high. Liquids have the ability to transmit heat faster than air cooling directly to the CPU, GPU and other components important.<\/span><\/p>\n<ul style=\"text-align: justify;\">\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Effect: Reduction of operating temperature from <\/span><b>10\u00b0C to 15\u00b0C<\/b><span style=\"font-weight: 400;\"> compared with air cooling.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Energy saving: Reduce <\/span><b>30%-50%<\/b><span style=\"font-weight: 400;\"> power consumption for the cooling system.<\/span><\/li>\n<\/ul>\n<h3>3.2. Design room server<\/h3>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Design space, server room, play a decisive role in the optimized airflow ensures uniform temperature between the regions.<\/span><\/p>\n<p style=\"text-align: justify;\"><b>Device layout optimal airflow (Hot aisle\/Cold aisle): <\/b><span style=\"font-weight: 400;\">This method divide the rack into two separate areas:<\/span><\/p>\n<ul style=\"text-align: justify;\">\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Cold aisle:<\/b><span style=\"font-weight: 400;\"> Towards the front of the rack cabinet at the entrance where the cold air is supplied from the cooling system.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Hot aisle:<\/b><span style=\"font-weight: 400;\"> The back of the rack guide on the heated walkways, where hot gases are collected and taken out of the room.<\/span><\/li>\n<\/ul>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Benefits: Reduce the average temperature in the server room. Save cooling costs up to <\/span><b>30%<\/b><span style=\"font-weight: 400;\">.<\/span><\/p>\n<p style=\"text-align: justify;\"><b>Insulation and room dimensions:<\/b><\/p>\n<ul style=\"text-align: justify;\">\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Insulation material:<\/b><span style=\"font-weight: 400;\"> Use wall insulation, doors sealed to prevent the intrusion of outside temperature.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Room size:<\/b><span style=\"font-weight: 400;\"> Server room that is too small will restrict airflow, causing the phenomenon of heat accumulation.<\/span><\/li>\n<\/ul>\n<h3>3.3. Download heat from the device<\/h3>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">The heat generated from the device is also important factor affecting the room temperature, server.<\/span><\/p>\n<p style=\"text-align: justify;\"><b>The difference between the types of server:<\/b><\/p>\n<ul style=\"text-align: justify;\">\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Blade server:<\/b><span style=\"font-weight: 400;\"> With high-density blade server heat more than rack server and tower server. A blade server can generate the amount of heat from <\/span><b>4kW to 6kW<\/b><span style=\"font-weight: 400;\"> on each rack.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Rack server:<\/b><span style=\"font-weight: 400;\"> In accordance with the business SME, the heat generated usually from <\/span><b>1.5 kW to 3kW<\/b><span style=\"font-weight: 400;\"> on each rack.<\/span><\/li>\n<\/ul>\n<p style=\"text-align: justify;\"><b>The number of devices and download the work:<\/b><\/p>\n<ul style=\"text-align: justify;\">\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>The number of devices increases:<\/b><span style=\"font-weight: 400;\"> Increased device density means increased heat load in the room server, requiring the cooling system to operate with greater capacity.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Download high work:<\/b><span style=\"font-weight: 400;\"> The server continuous operation at high power, as when handling big data (big data), or AI, will produce large amounts of heat than the common tasks.<\/span><\/li>\n<\/ul>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Enterprises need to fully evaluate the factors that affect the temperature of the server room to design and operate the system accordingly. From the selection of cooling system design, space to manage the heat load from the device, each element plays an important role in maintaining the room temperature, server stability, protecting your IT assets long-term.<\/span><\/p>\n<h2>4. The impact of temperature does not reach the standard to server system<\/h2>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Nhi\u1ec7t \u0111\u1ed9 ph\u00f2ng server kh\u00f4ng \u0111\u1ea1t ti\u00eau chu\u1ea9n c\u00f3 th\u1ec3 g\u00e2y ra nh\u1eefng h\u1eadu qu\u1ea3 nghi\u00eam tr\u1ecdng, kh\u00f4ng ch\u1ec9 \u1ea3nh h\u01b0\u1edfng \u0111\u1ebfn hi\u1ec7u su\u1ea5t ho\u1ea1t \u0111\u1ed9ng c\u1ee7a h\u1ec7 th\u1ed1ng m\u00e0 c\u00f2n l\u00e0m t\u0103ng nguy c\u01a1 gi\u00e1n \u0111o\u1ea1n v\u1eadn h\u00e0nh doanh nghi\u1ec7p.<\/span><\/p>\n<p style=\"text-align: center;\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-43428\" src=\"https:\/\/lacviet.vn\/wp-content\/uploads\/2024\/12\/tieu-chuan-nhiet-do-phong-server-2.png\" alt=\"\" width=\"800\" height=\"500\" srcset=\"https:\/\/lacviet.vn\/wp-content\/uploads\/2024\/12\/tieu-chuan-nhiet-do-phong-server-2.png 800w, https:\/\/lacviet.vn\/wp-content\/uploads\/2024\/12\/tieu-chuan-nhiet-do-phong-server-2-768x480.png 768w, https:\/\/lacviet.vn\/wp-content\/uploads\/2024\/12\/tieu-chuan-nhiet-do-phong-server-2-18x12.png 18w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">D\u01b0\u1edbi \u0111\u00e2y l\u00e0 nh\u1eefng t\u00e1c \u0111\u1ed9ng c\u1ee5 th\u1ec3:<\/span><\/p>\n<h3>4.1. Reduce performance of the device<\/h3>\n<ul style=\"text-align: justify;\">\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Overheating (Overheating)<\/b><span style=\"font-weight: 400;\">: The devices such as CPU, hard drives, power supplies operate continuously generate large amounts of heat. If the cooling system is not effective or ambient temperature exceeds 27\u00b0C, rising temperatures will trigger mechanism, reduce the pulse rate of the CPU (thermal throttling) to protect the hardware. This significantly reduces the processor performance data.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Performance decreased abruptly<\/b><span style=\"font-weight: 400;\">: A study by Microsoft showed that when the temperature exceeds 30\u00b0C, the error rate data in system storage increased <\/span><b>25%<\/b><span style=\"font-weight: 400;\">.<\/span><\/li>\n<\/ul>\n<h3>4.2. Increase the risk of hardware failure<\/h3>\n<ul style=\"text-align: justify;\">\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Damage to electronic components<\/b><span style=\"font-weight: 400;\">: High temperature increases the thermal expansion of the components, causing cracked welds or circuit error. Hard drive HDD and SSD are particularly sensitive to high temperatures; according to data from Backblaze, the temperature exceeds 40\u00b0C reduce the lifespan of the hard drive at <\/span><b>15%-20%<\/b><span style=\"font-weight: 400;\">.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Static electricity due to low humidity<\/b><span style=\"font-weight: 400;\">: \u0110\u1ed9 \u1ea9m kh\u00f4ng \u0111\u1ea1t ti\u00eau chu\u1ea9n (&lt;40%) c\u00f3 th\u1ec3 t\u1ea1o ra t\u0129nh \u0111i\u1ec7n, d\u1eabn \u0111\u1ebfn nguy c\u01a1 ch\u1eadp m\u1ea1ch ho\u1eb7c h\u01b0 h\u1ecfng linh ki\u1ec7n nh\u1ea1y c\u1ea3m.<\/span><\/li>\n<\/ul>\n<h3>4.3. Increased downtime and operating costs<\/h3>\n<ul style=\"text-align: justify;\">\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Increase the proportion of downtime<\/b><span style=\"font-weight: 400;\">: According to reports of Uptime Institute, 1\u00b0C increase above the standard can increase the rate of downtime up to <\/span><b>2%<\/b><span style=\"font-weight: 400;\"> each year. Downtime not only cause disruptions that also affect the reputation, causing financial losses severe.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Rising cost of repair replacement<\/b><span style=\"font-weight: 400;\">: When the temperature is not standardized, the components and hardware vulnerable to damage early, increasing maintenance costs. A study by IBM showed not maintain the ideal temperature increases the cost of hardware repairs up to <\/span><b>35%<\/b><span style=\"font-weight: 400;\"> every year.<\/span><\/li>\n<\/ul>\n<h3>4.4. Affect energy and the environment<\/h3>\n<ul style=\"text-align: justify;\">\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Power consumption rising<\/b><span style=\"font-weight: 400;\">: When the room temperature, server exceeds the threshold, the cooling system must operate at full capacity, increases energy costs. Data from Schneider Electric to see the cooling system occupies <\/span><b>40%-50% of the total energy consumption<\/b><span style=\"font-weight: 400;\"> of the server room.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Carbon emissions<\/b><span style=\"font-weight: 400;\">: High energy consumption not only increases the cost but also increase CO2 emissions, affect is committed to protecting the environment of the business.<\/span><\/li>\n<\/ul>\n<h2>5. System, control room temperature, server efficiency<\/h2>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">To ensure <\/span><b>standard room temperature, server<\/b><span style=\"font-weight: 400;\">businesses need to apply the control solution to effectively manage. Here are the specific measures:<\/span><\/p>\n<h3>5.1. Cooling system optimal<\/h3>\n<ul style=\"text-align: justify;\">\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Air conditioning system for professional use (Precision Cooling)<\/b><span style=\"font-weight: 400;\">: Air conditioning, dedicated server room have the ability to control temperature, humidity exactly help maintain ideal conditions 24\/7.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>The cooled stream of hot air \u2013 conditioning (Hot and Cold Aisle Containment)<\/b><span style=\"font-weight: 400;\">: Dividing the area of hot air \u2013 cold in the server room to optimize airflow, reduce uneven temperatures. This pattern has been companies such as Google, Amazon apply to save up to <\/span><b>30% cooling energy<\/b><span style=\"font-weight: 400;\">.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Liquid Cooling System<\/b><span style=\"font-weight: 400;\">: This is the advanced solution, using liquid cooling direct components, higher efficiency than the system air cooled transmission system.<\/span><\/li>\n<\/ul>\n<h3>5.2. Sensor temperature and humidity smart<\/h3>\n<ul style=\"text-align: justify;\">\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Sensor IoT<\/b><span style=\"font-weight: 400;\">: These sensors track temperature, humidity, real-time automatically send alert when exceeding the threshold standards help businesses react promptly to prevent the risk rising temperatures.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Management system, automatic temperature<\/b><span style=\"font-weight: 400;\">: Use integrated software AI to adjust airflow, the operation of the system cooling based on the temperature data, the actual.<\/span><\/li>\n<\/ul>\n<h3>5.3. Periodic maintenance and suitable design<\/h3>\n<ul style=\"text-align: justify;\">\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Periodic maintenance cooling system<\/b><span style=\"font-weight: 400;\">: Sanitary inspection, periodic cooling devices, to ensure performance.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Room design server sciences<\/b><span style=\"font-weight: 400;\">: Ensure space large enough to avoid temperature cornered department. Arrange a rack reasonable to optimize airflow.<\/span><\/li>\n<\/ul>\n<h3>5.4. App advanced technology<\/h3>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Modern technology plays an important role in the control of room temperature, server help improve operational efficiency, save energy.<\/span><\/p>\n<p style=\"text-align: justify;\"><b>AI and IoT in automatic temperature adjustment<\/b><\/p>\n<ul style=\"text-align: justify;\">\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>AI (artificial intelligence):<\/b><span style=\"font-weight: 400;\"> The cooling system integrated AI can analyze data, temperature, heat load, air flow in real time to automatically adjust cooling capacity. Help reduce waste energy, preventing overheating in areas critical.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>IoT (Internet of Things):<\/b><span style=\"font-weight: 400;\"> Sensors, IoT devices are installed at different positions in the server room for continuous monitoring of parameters such as temperature, humidity, air pressure. This data is sent on the control center to make timely adjustments, ensured temperature stability.<\/span><\/li>\n<\/ul>\n<p><b>Benefits: <\/b><span style=\"font-weight: 400;\">Reduce energy consumption cooling to <\/span><b>20%-30%<\/b><span style=\"font-weight: 400;\">. Increase efficiency, temperature control in each zone in the server room.<\/span><\/p>\n<h3>5.5. Optimal energy cost<\/h3>\n<ul style=\"text-align: justify;\">\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Renewable energy sources<\/b><span style=\"font-weight: 400;\">: Applied solar or wind to provide power for the cooling system, just save costs and reduce carbon emissions.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Optimize PUE (Power Usage Effectiveness)<\/b><span style=\"font-weight: 400;\">: Track indicator PUE to assess the efficient use of energy, thereby improving the system. The PUE is the ideal <\/span><b>under 1.5<\/b><span style=\"font-weight: 400;\"> according to the international standard.<\/span><\/li>\n<\/ul>\n<h2>6. Vietnam \u2013 a comprehensive Solution for server room business<\/h2>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">To ensure standard room temperature, server, enterprises need to choose the professional partner in the design and construction of infrastructure systems. Cooperation with service provider reputation not only ensure quality but also bring solutions to optimize cost, efficiency long-term.<\/span><\/p>\n<p style=\"text-align: justify;\"><b>The importance of the cooperation with reputable vendors:<\/b><\/p>\n<ul style=\"text-align: justify;\">\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Our team of professionals have the experience to ensure fit design operating needs of the business.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Comprehensive review about the location, heat load and the specific requirements of the IT system to the proposed cooling solution the most effective.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Maintenance support system upgrades periodically, reduce risk damage due to temperature.<\/span><\/li>\n<\/ul>\n<p style=\"text-align: justify;\"><b><i>Lac Viet is the pioneer in the field of design, construction, system, server room international standard:<\/i><\/b><\/p>\n<p style=\"text-align: justify;\"><b>In-depth experience:<\/b><span style=\"font-weight: 400;\"> More <\/span><b>30 years of experience<\/b><span style=\"font-weight: 400;\"> with a team of professional technicians, understanding the standard temperature cooling modern.<\/span><\/p>\n<p style=\"text-align: justify;\"><b>Comprehensive solution:<\/b><\/p>\n<ul style=\"text-align: justify;\">\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Design consultants cooling system in accordance with the scale, the peculiarities of each business.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Deployment of advanced technologies such as AI, IoT, liquid-cooled.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Provide service, maintenance, continuous optimization after construction.<\/span><\/li>\n<li aria-level=\"1\">Solution provider <a href=\"https:\/\/lacviet.vn\/en\/fm-200-fire-suppression-system\/\">FIRE protection server room<\/a> with technology F200 most advanced<\/li>\n<\/ul>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Vietnam has successfully implemented hundreds of projects room server help businesses reduce operating costs, enhance system performance.<\/span><\/p>\n<blockquote><p>&gt;&gt;&gt; <em>Gi\u1ea3i ph\u00e1p li\u00ean quan: Xem b\u00e1o gi\u00e1 m\u00e1y ch\u1ee7 <strong><a href=\"https:\/\/lacviet.vn\/en\/may-chu-dell-poweredge-server\/\">Server Dell<\/a> <\/strong>for business<\/em><\/p><\/blockquote>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Maintaining <\/span><b>standard room temperature, server<\/b><span style=\"font-weight: 400;\"> is a core element to ensure the system IT works stable and sustainable. Businesses not only need to apply the advanced technology, but also need to cooperate with unit design and construction of prestige such as Vietnam to optimize efficiency and minimize risk in the operation.<\/span><\/p>","protected":false},"excerpt":{"rendered":"<p>Trong k\u1ef7 nguy\u00ean s\u1ed1, h\u1ec7 th\u1ed1ng m\u00e1y ch\u1ee7 server \u0111\u00f3ng vai tr\u00f2 quan tr\u1ecdng trong h\u1ea1 t\u1ea7ng c\u00f4ng ngh\u1ec7 th\u00f4ng tin doanh nghi\u1ec7p. Vi\u1ec7c duy tr\u00ec nhi\u1ec7t \u0111\u1ed9 ph\u00f2ng server trong ng\u01b0\u1ee1ng ti\u00eau chu\u1ea9n kh\u00f4ng ch\u1ec9 \u0111\u1ea3m b\u1ea3o hi\u1ec7u su\u1ea5t ho\u1ea1t \u0111\u1ed9ng m\u00e0 c\u00f2n gi\u00fap t\u0103ng tu\u1ed5i th\u1ecd thi\u1ebft b\u1ecb, gi\u1ea3m thi\u1ec3u r\u1ee7i ro gi\u00e1n [&hellip;]<\/p>\n","protected":false},"author":8,"featured_media":43307,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[34],"tags":[92],"class_list":["post-43276","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-quan-tri-ha-tang-so","tag-server"],"_links":{"self":[{"href":"https:\/\/lacviet.vn\/en\/wp-json\/wp\/v2\/posts\/43276","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lacviet.vn\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/lacviet.vn\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/lacviet.vn\/en\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/lacviet.vn\/en\/wp-json\/wp\/v2\/comments?post=43276"}],"version-history":[{"count":6,"href":"https:\/\/lacviet.vn\/en\/wp-json\/wp\/v2\/posts\/43276\/revisions"}],"predecessor-version":[{"id":44335,"href":"https:\/\/lacviet.vn\/en\/wp-json\/wp\/v2\/posts\/43276\/revisions\/44335"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/lacviet.vn\/en\/wp-json\/wp\/v2\/media\/43307"}],"wp:attachment":[{"href":"https:\/\/lacviet.vn\/en\/wp-json\/wp\/v2\/media?parent=43276"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/lacviet.vn\/en\/wp-json\/wp\/v2\/categories?post=43276"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/lacviet.vn\/en\/wp-json\/wp\/v2\/tags?post=43276"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}